IEC 61010

IEC 61010

 
IEC 61010

Company News

Earthing Resistance Test

1. Purpose:

The requirements are specified in order to ensure that exposed metal is effectively
connected to the main earth terminal of the appliance.

2. Application:

Class 0I and class I appliance.

3. Test Apparatus:

Having a no-load voltage not exceeding 12 V (a.c. or d.c.) and equal to 1.5 times rated
current of the appliance or 25 A, whichever is the greater.

4. Special Instruction:

a. The resistance of flexible cable or cord is not included in the measurement.

b. Care is taken that the contact resistance between the tip of measuring probe and
the metal part under test does not influence test result.

c. Current is passed between the earthing terminal or earthing contact and each of
the accessible metal parts in turn.

5. Test Procedure:

a. Connect the test probe to the earthing terminal or earthing contact and the
accessible metal parts.

b. Adjust the test equipment until the current reach 1.5 times rated current of the
appliance or 25 A, whichever is the greater. The test period set at 60s.

c. Press the test button and read the maximum resistance.

6. Evaluation of test result:

The earthing resistance shall not exceed 0.1 Ω

    Standard:       IEC 61032 IEC 60061 IEC 60335 IEC 60529 IEC 60068 IEC 60950 IEC 61010 IEC62368 IEC 60601
    TAG:
Test Probe Go Not Go Gauges Spring Impact Hammer Test Pin Probe Test Probe B Test Probe 18 IP Test Probe
 
Lampholder Gauges Lampcap Gauge Test Probe 11 UL Test Finger Probe Test Vessel Rigid Test Finger Impact Testing
test probe