IEC 61010
 
IEC 61010

Company News

Creepage and Clearance: Measuring the Shortest Path That Is Rarely the Obvious One

Creepage and clearance are the two distances that decide whether an insulation design works. They are defined differently — one follows the surface, the other passes through air — and on a real assembly the two paths are rarely the straight lines a drawing suggests.

The definitions, stated plainly

Clearance is the shortest distance through air between two conductive parts. Creepage is the shortest distance along the surface of the insulating material between the same two parts. A rib increases creepage without increasing clearance; a slot does the same; a groove narrower than the specified minimum width may be ignored entirely, so the creepage path bridges across it.

This last point catches more designs than any other. A 0.8 mm groove between two tracks looks like it adds 0.8 mm of creepage. If the applicable minimum groove width is 1 mm, the groove is disregarded and the creepage is measured straight across — no benefit at all.

Where the path is not where you think

FeatureEffect on clearanceEffect on creepage
Ribnonefollows the rib contour
Slot wider than the minimumnonefollows the slot walls
Slot narrower than the minimumnonebridged, no benefit
Conformal coatingnonemay allow reduced distance if qualified

Pollution degree and material group

The required distance is not a single number. It depends on the pollution degree of the environment, the material group of the insulation, and the working voltage. Pollution degree 2 — the usual assumption for office and laboratory equipment — assumes only non-conductive pollution with occasional condensation. Pollution degree 3 assumes conductive pollution or dry non-conductive pollution that becomes conductive with condensation, and requires substantially larger distances.

Material group is set by the comparative tracking index of the insulation: group I at 600 V and above, group II at 400 to 599 V, group IIIa at 175 to 399 V. A material change from group II to group IIIa at the same working voltage can increase the required creepage by 30 % or more, which is why substituting "an equivalent plastic" is rarely equivalent.

How to measure it defensibly

Use the shortest path, not the most convenient one. The measurement follows the surface around every contour, including the sides of a terminal block and the inside of a housing wall. A caliper across the top is not a creepage measurement.

Measure at the worst point. Assemblies are not uniform. The distance that matters is the smallest one anywhere between the two parts, which is often at a corner where two mouldings meet with a small gap.

Record the path, not just the number. A note that says "8 mm" is unusable in an audit. A photograph with the path drawn on it, plus the standard clause and the assumed pollution degree, can be reviewed by someone else.

The design lesson

Creepage is usually fixed at the moulding stage, not at assembly. A housing designed without ribs cannot be made compliant by adding a coating afterward, and a PCB laid out with 3 mm between tracks cannot be fixed by re-routing one trace. The cheap moment to get this right is the first drawing review; every later moment is expensive.

    Standard:       IEC 61032 IEC 60061 IEC 60335 IEC 60529 IEC 60068 IEC 60950 IEC 61010 IEC62368 IEC 60601
    TAG:
Test Probe Go Not Go Gauges Spring Impact Hammer Test Pin Probe Test Probe B Test Probe 18 IP Test Probe
 
Lampholder Gauges Lampcap Gauge Test Probe 11 UL Test Finger Probe Test Vessel Rigid Test Finger Impact Testing
test probe