A temperature rise limit is a way of translating insulation life into a number that can be measured in a workshop. A class B winding at 90 K rise in a 40 °C ambient sits at 130 °C, which is the class limit minus the hot-spot allowance.
Read that way, the table stops being arbitrary. Every limit is a class limit with the ambient and the manufacturing tolerance already subtracted.
The limits that matter
| Part | Limit | What it protects |
| Class A winding | 60 K | 105 °C class limit |
| Class B winding | 90 K | 130 °C class limit |
| Class F winding | 115 K | 155 °C class limit |
| Enclosure, metal, accessible | 30 K to 40 K | Touch temperature and internal components |
| Enclosure, plastic, accessible | 40 K to 70 K | Material softening and touch |
| Terminals and wiring | 45 K to 60 K | Insulation ageing at the joint |
| Transformer core | Not to exceed the class of its insulation | Local hot spots |
The accessible surface limits sit lower than the internal ones because a person touches them. A metal handle at 70 K rise from a 25 °C room is 95 °C, which is a burn, not a discomfort.
How the measurement is made
- Thermocouples, not infrared. A surface pyrometer reads the emissivity of the paint, not the part.
- Attach with a method that does not cool the part. Cemented fine wire, or a small pad; tape over a thermocouple insulates it.
- Soak until three readings in ten minutes differ by less than 1 K. Most products need two to four hours.
- Worst-case supply. 1.06 times rated voltage for heating tests in many product standards.
What to do when the limit is exceeded
First decide whether the excess is real or an artefact: a thermocouple taped to a winding reads the tape, and a measurement taken before thermal equilibrium reads low. Then look at the three usual causes, in order: too little copper, too little airflow, and a thermal path through a plastic boss that was designed for strength rather than for heat.
The fix that almost never works is a fan. It changes the result in the laboratory and hides the design problem until a filter clogs. Our temperature rise test sets include the thermocouple kit and the logging instrument, and the technical notes cover the soak times per product family.
Standards referenced: IEC 61010-1 clause 10.3 and Table 8, IEC 60335-1 Table 3, IEC 60085 for thermal classes.
The 1.06 factor and the 40 °C ambient
Heating tests are run at 1.06 times the rated voltage because the worst case is a high supply, not a low one. The ambient is 40 °C because that is the reference for the declared limits; a product rated for 25 °C needs its own table and its own justification.
Record ambient within 2 K of the test room, and note any draught: a fan in the corner of the laboratory can change a winding reading by 5 K.