The earth continuity test is the simplest safety test in the set and the one with the most variable practice. Apply a current between the protective earth terminal and an accessible metal part, measure the resistance, compare with a limit. The argument is always about how much current and for how long.
Each of the three numbers answers a different worry, and confusing them produces tests that are either meaningless or destructive.
What the three numbers do
| Parameter | Common value | Purpose |
| Test current, equipment | 25 A AC or DC | Proves the bond carries fault current |
| Test current, cord-connected | 10 A to 25 A depending on the standard | Adapted to the conductor size |
| Higher current option | 40 A | Stresses a bond that will see high fault current |
| Resistance limit | 0.1 Ω including the test leads, or 0.1 Ω plus the cord | Low enough that the protective device operates |
| Duration | 1 minute, or until stable | Lets the bond heat and reveal a poor joint |
| Short option | A few seconds at a higher current in some standards | Production speed |
The 0.1 Ω figure comes from the fault loop, not from the bond alone. A protective device has to trip within its time, and the loop impedance includes the supply, the cord and the bond. A bond of 0.1 Ω plus a cord of 0.2 Ω plus a supply of 0.3 Ω is already at the point where a 16 A breaker may not trip fast enough; the bond limit is a portion of a budget, not a property of the metal.
Why current and time are linked
A bond that measures 0.08 Ω cold can measure 0.3 Ω after a minute at 25 A if the joint is a single screw on painted metal: the paint carbonises, the contact area falls and the resistance rises. The minute is not there to be endured, it is there to make the joint fail if it is going to.
A two-second test at the same current will pass that joint. This is the origin of the shorter options in some standards: they are accepted only where the joint design has been qualified by the longer test, which is a different statement from "two seconds is equivalent".
Making the measurement
- Four-wire, or accept the lead error. At 0.1 Ω a pair of test leads can be 0.03 Ω, which is a third of the limit.
- Probe the metal, not the paint. A reading taken through powder coat is a reading of the powder coat.
- Probe each accessible part separately. A bonded lid does not prove a bonded base.
- Watch the trend during the minute. A resistance that climbs is a joint failing under test, and it is the most valuable result the test produces.
Failures worth reporting separately
Distinguish an open bond from a high-resistance bond. An open bond is a missing wire or a screw into plastic. A high-resistance bond is a screw into paint, a star washer that has been omitted, or a terminal that has been crimped onto insulation. The first is an assembly error, the second is a design error, and they need different corrective actions even though both fail the same limit.
Record the current, the duration, the resistance at the start and at the end, and the points probed. A earth bond tester with a four-wire measurement and a timed output makes the test repeatable, and the site index lists the testers by current range.
Standards referenced: IEC 61010-1.