IEC 61010
 
IEC 61010

Company News

Creepage and Clearance in IEC 61010-1: The Four Inputs and the Measurement Path

Creepage and clearance calculations look like a table lookup. In practice most disagreements come from the inputs, not the table: what counts as working voltage, how the pollution degree was assigned, which material group applies, and where the measurement path actually runs. Get those four right and the numbers follow.

Clearance and creepage are different paths

Clearance is the shortest distance through air between two conductive parts. Creepage is the shortest distance along the surface of the insulating material. A slot in a moulding increases the creepage path but not the clearance. A rib increases creepage if it is tall enough relative to the gap; a shallow rib may be ignored. This is why a drawing review without a physical sample often produces the wrong number.

The four inputs

Working voltageThe actual voltage across the insulation in normal operation, including overvoltage from the supply. It is not always the mains nominal value: a transformer winding or a switched node can be higher.
Pollution degree1 for sealed or potted assemblies, 2 for ordinary laboratory equipment, 3 for dirty or outdoor environments. The degree is a property of the microenvironment, not the room.
Material groupDerived from the comparative tracking index of the insulation: I for the highest tracking resistance, IIIb for the lowest. A material group taken from a datasheet must match the actual moulding compound.
Overvoltage categorySets the transient level the clearance must withstand. Equipment connected to the mains at the origin of an installation is treated differently from equipment downstream.

Measuring the path

Use the actual assembly. Mark the shortest path with a fine thread or a soft wire, then measure it. Points that catch people out:

  • A path that runs around the end of a barrier is longer than it looks on a 2D drawing, but a path that crosses a joint between two parts may be shorter than either part suggests.
  • Conformal coating can change the creepage requirement, but only if the coating is qualified and continuous over the joint. A coating that stops at a connector does not help there.
  • Clearance through a hole is measured through the hole, not around it.
  • Creepage along a slot is measured into and out of the slot if the slot is wide enough to be counted.

Where the numbers come from

IEC 61010-1 gives the clearance and creepage tables in clause 6.7, with values that depend on the four inputs above. Two habits keep the calculation defensible:

  1. Write the input values down before opening the table, and attach the evidence: CTI test report, pollution degree justification, working voltage measurement.
  2. Round in the conservative direction. If the measured path is 1.9 mm and the table requires 2.0 mm, the design fails; a rounding argument will not survive a review.

The mistakes that repeat

  • Using the rated supply voltage as working voltage on the secondary side of a transformer.
  • Assigning pollution degree 2 to a compartment that collects dust because the room is clean.
  • Taking material group from a generic datasheet while the production moulding uses a different grade.
  • Measuring creepage across a gap that is actually bridged by a metal insert.

Documenting the result

A creepage and clearance review should produce a table per insulation path: from part, to part, working voltage, pollution degree, material group, required clearance, measured clearance, required creepage, measured creepage, verdict. That table is what a test house will ask for, and it is what makes a design change reviewable. The test equipment catalogue includes the probes and gauges used to verify accessibility and spacing, and the IEC test probe range covers the finger and probe geometry referenced by the standard.